Kanomax 6710 TABmaster Capture Hood User Manual User Manual

Browse online or download User Manual for Tools Kanomax 6710 TABmaster Capture Hood User Manual. KANOMAX 6710 TABmaster Capture Hood User Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CAPTURE HOOD
MODEL 6710
INSTRUCTION MANUAL
Be sure to read this manual thoroughly before using the instrument.
Fully understand and pay attention to each caution mentioned.
Please keep this manual as a service reference.
01001
1 2 10
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - CAPTURE HOOD

CAPTURE HOOD MODEL 6710 INSTRUCTION MANUAL Be sure to read this manual thoroughly before using the instrument. Fully underst

Page 2

3 2.2 Main structure  2.3 Fabric Hood The fabric hood kit consists of a frame, and a fabric hood with four windows as shown below: 3. Inst

Page 3 - Composition & Parts

4 2)The figures below are provided as a reference. a. Use the mark ① and the stitching as a guide to ensure the hood position. b. Make sure the

Page 4 - WARNING

5 3.4 Installing the Main structure To install the Main structure ①, set the bottom of the panel in the holder on the unit base ② and gently push th

Page 5 - CAUTION

6 4.2 Supplying Power with Batteries ¾ 4 AA-size batteries can be used for a power supply. ¾ Press the compartment cover lock (refer to figure ①),

Page 6 - CONTENTS

7 4.3 ON/OFF 1. Getting started The LCD is displayed below for reference: 2. Shut down Press and hold 【POWER】for more than 2 seconds in any

Page 7

8 z SAVE: Save the current test results. z SET: Store changes or enter into the selected option’s next level interface. z MENU: On the main screen

Page 8 - 1.Introduction

9 Note: 1. The instrument may turn off, when you attempt to adjust the incline settings of the instrument if the battery display is at

Page 9 - 2. Capture Hood Structure

10 4.7 Measuring 4.7.1 Start and enter into the main interface To start measuring, go to the main interface menu as shown below: a. Test ID

Page 10

11 1)“Single” measurements are individual flow measurements. When you press “START”, the instrument will begin measuring and the air flow value will

Page 11

12 4.7.4 Back Pressure Compensation Measurement Mode When measuring air flow in an environment with a strong wind or turbulent flow, it will produce

Page 12 - 4. Operation directions

Thank you for your purchasing a KANOMAX instrument. This is a precision instrument, please read this instruction manual carefully before using th

Page 13

13 5.1 Test Settings (1)Press or to select “Test Settings”, and press to enter into “Test Settings”. Press

Page 14 - 4.4 Keypad Operation

14 5.1.1 Test ID setting A Test ID consists of a group of Cycles (or Samples). A Test ID can contain up to 100 Cycles. The maximum number of Test I

Page 15

15 5.1.2 Test Mode settings This setting is for change the test mode & the settings about the test modes. Refer to the steps below: ¾

Page 16

16 5.1.3 Set Units of Measure for Airflow, Temperature and Atmos For available units, refer to the below chart: To change the units of measur

Page 17 - 4.7 Measuring

17 5.1.4 Actual flow, Standard flow settings This setting is for selecting Actual air flow [ACT] or Standard air flow [STD]. ¾ Under the “Test Se

Page 18

18 5.2 General Settings ¾ Under “MENU”, select option 2 “General Settings”. ¾ Press to enter “General Settings” or press to return to the m

Page 19 - 5. Display Menu settings

19 5.3 Data processing settings ¾ Under “MENU” select option 3 “Record Processing”. ¾ Press to select “Record Processing”. Press to

Page 20 - 5.1 Test Settings

20 ¾ Press or to select option item as below. ¾ Press for 2 seconds to save the changes or press t to quit. ¾ Press

Page 21 - 5.1.1 Test ID setting

21 5.5 Print Settings Note:Before printing ensure the following: 1. Please select the factory configuration printer and printer cable. For details,

Page 22 - 5.1.2 Test Mode settings

22 ¾ Press or to select the “Start ID” value. ¾ Press to save or press to quit. ¾ Press or to select the “S

Page 23 - Test Settings

Composition & Parts  Standard part: Model No. Functions 6710 Air quantity/temperature/humidity  Standard components: Items Qty Main stru

Page 24

23 6.Main Specifications Items 6710 Air Flow Flow range 40~4300 m³/h Accuracy Readings ±3%± 10 m³/h(Air Flow >85 m³/h) Resolution 1 m³/h Temper

Page 25 - 5.2 General Settings

24 7. Common Trouble Shooting Symptom Possible causes / troubleshooting No display Check the positive/negative connections of the batteries. →Verif

Page 26 - 5.3 Data processing settings

25 8. Warranty and After-service 8.1 Warranty  Seller warrants the goods sold hereunder, under normal use and service as described in the operator

Page 27 - 5.4 Communication settings

□CHINA SHENYANG KANO SCIENTIFIC INSTRUMENT CO., LTD. #2610, 51 Wulihe Street, Heping District, Shenyang PRC. TEL: 024-23846440 83951688 83

Page 28 - 5.5 Print Settings

iATTENTIONS & NOTES The warning symbols mentioned in this manual are defined below: 〔symbol classifications〕 Danger: To Prevent Serious Injury or

Page 29 - Print By IDs

ii DANGER Forbidden z Do not exposure the instrument to rain or water. …… Otherwise, it may cause an electric shock, fire or injury.

Page 30 - 6.Main Specifications

1 CONTENTS 1.Introduction ... 1

Page 31 - 7. Common Trouble Shooting

2 5.1.4 Actual flow, Standard flow settings ... 17 5.2 General settings ...

Page 32 - 8.2 After-service

1 1.Introduction The model 6710 is used to measure the air flow at the supply and the exhaust points of an HVAC system. There are several interchan

Page 33 - □JAPAN KANOMAX JAPAN, INC

2 2. Capture Hood Structure The capture hood consists of a fabric hood, main structure and an instrument base. The structural drawing is below: